The Deliberate Power Cut: A Calm 30-Minute Rehearsal for Your Home Tech
Power cuts are boring right up until the moment they are not. The lights go out, the broadband drops, the smart speaker stops answering, and someone asks whether the freezer is going to be all right. In 2026 our homes are full of small computers that all expect mains power, and most of us have only a vague idea which ones survive a storm outage and which ones fall over immediately.
A deliberate power-cut rehearsal fixes that. It is not a prepper exercise and it does not require a generator in the shed. Think of it as a fire drill for your fuse board: thirty minutes on a quiet Sunday morning, a notebook, and a willingness to unplug a few things on purpose.
First, decide what you are actually testing
You do not need to simulate a national grid failure. The useful questions are narrower. Does the internet stay up? Can the NAS shut down gracefully? Do the smart-home hubs keep talking to sensors? Will the work laptop still get online if the router is dead?
Pick two or three of those. A whole-house test sounds dramatic, but it mostly teaches you that the fridge is warm and the oven clock has reset. A targeted test tells you whether the openreach ONT in the hallway is on the same UPS as the router, which is the sort of detail that matters at 7am on a Monday.
Safety first, as ever. Tell everyone in the house what is happening. Do not include medical equipment, smoke alarms, or the freezer in the test. The safest version is to unplug the devices you are testing and run them from the UPS, rather than flipping switches in the consumer unit. If you do use the consumer unit, only touch the labelled socket circuit and leave everything else alone. If you are not confident, get an electrician. This is meant to be a rehearsal, not an incident.
The half-hour plan
Spend the first five minutes writing down what is plugged in where. Use a plug-in energy monitor if you have one; it takes seconds to read the watts for the router, ONT, hub and NAS. Guesswork is fine for a first pass, but real numbers make UPS sizing much less mysterious.
The next five minutes are for labelling. More on that below, but the short version is that every essential plug gets a clear name and a clear instruction. 'Router — UPS 1' is useful. 'Black plug, hallway' is not.
Then run the test for fifteen minutes. Pull the mains plug on the UPS, or switch off the socket circuit if you are confident, and watch what happens. Note the time. Does the router stay up? Does the ONT? Does the hub reconnect to sensors? Does the NAS start beeping? Can the laptop still reach the internet?
Use the last five minutes to restore power in a sensible order and write down what you learned. The whole thing should feel slightly dull. That is the point.
What actually stays alive
The router and ONT are the pair people forget. A UPS in the study might keep the router alive while the ONT in the hallway dies, which means no internet despite a glowing UPS. Both need to be on battery backup if you want broadband during an outage. A typical router draws around 10–15W and an ONT around 5–10W, so a small UK three-pin UPS can run them for a decent stretch — but check the runtime chart rather than trusting the box.
Smart-home hubs are more variable. Many mains-powered Zigbee or Z-Wave hubs simply stop when the power goes. Battery sensors may still send messages, but there is nothing to receive them. If your lights and heating depend on the hub, decide whether it belongs on the UPS or whether you are happy to lose automations for an hour.
A NAS is the device that deserves the most care. It should be on a UPS with a USB data cable so it can shut itself down before the battery dies. Test that shutdown routine during the drill. A NAS that loses power abruptly can survive, but it can also corrupt files, and nobody wants to discover that during a storm.
The work laptop is usually fine. Its battery gives you a couple of hours, but only if the Wi-Fi still works. If the router is not backed up, tethering to a phone is the practical fallback. Test that too, while you are at it.
Sizing a UK three-pin UPS without maths panic
UPS labels show VA and W. Ignore the big VA number for sizing and add up the watts. A 600VA unit is often rated around 360W, which sounds generous until you realise that runtime falls sharply as load rises. At 25W — router, ONT and a small hub — a decent 600VA unit might run for an hour or more. At 100W it might manage fifteen to twenty minutes. Manufacturer runtime charts are the only figures worth trusting.
For a NAS, look for a pure sine wave UPS if the manufacturer recommends it. Cheaper stepped-approximation units are often fine for routers and ONTs, but check the power supply. Buy a model with UK BS 1363 sockets, avoid daisy-chaining extension leads, and never plug a heater, laser printer or kettle into a UPS. Label the battery-backed outlets so nobody accidentally charges a drill from the wrong socket.
Label the plugs that matter
A label printer is nice, but masking tape and a marker work. Use one colour for UPS-backed plugs and another for 'restore first'. Write the device name and the action: 'ONT — do not switch off', 'NAS — shut down before UPS', 'Router — UPS 1'. Put a simple diagram inside the consumer unit if you have one, and keep it legible for a tired person with a torch.
The goal is that a future outage produces calm instructions rather than a family debate in the hallway. Essential plugs should be obvious. Non-essential ones should be obviously non-essential.
Make the next storm boring
Restore power in a sensible order: router and ONT first, then the hub, then the NAS. Check that smart routines still work and that nothing has lost its settings. Note any device that needed a manual nudge.
Then diarise the next drill for six months' time. Replace UPS batteries every three to five years, keep the units ventilated, and test the alarm. A thirty-minute rehearsal now is far less annoying than a chaotic hour in January. The best blackout is the one where nothing surprising happens.